Signal conditioning for PC based measurement |
| |
Miniature Measured Value Transformers SAM - Modules |
| |
About SAM modules: |
SAM modules are high-quality measured value transformers, which make the structure possible of compact
signal conditioning units in the PC measuring technique.
They can be inserted in SAM module boxes or into OEM specific carrier systems.
Both the module box and the carrier system contain auxiliary energy and the adapter
to the PC measuring board.
Each SAM module makes a measuring channel available.
SAM modules are available for many measuring sensors - voltage, current, PT100, thermocouples, ICP, bridge
signals - with or without galvanic signal isolation.
All modules have a bipolar 10V output signal range.
The development and manufacturing of the SAM module technology take place under employment of modern elements,
|
General technical data for SAM-Modules |
| |
Auxiliary energy: |
±15V DC ±5% |
| |
Design: |
Plug-in module |
| |
Surface area: |
24,5 x 72,5 mm |
| |
Overall height: |
max. 20mm |
| |
Connector: |
2 pin rows RM2,54mm |
| |
Bolting device: |
Screw M2,5 |
| |
Dimensional drawing: |
M2410002 |
|
 |
|
 |
The SAM module box S1 has a durable aluminum housing and offers place for 5 SAM modules.
It contains also the current supply and the connecting adapter to the PC measuring board. The auxiliary energy
of the SAM modules is galvanically isolated from the supply voltage of the box.
The connection of the measuring signals is made either by BNC sockets or 4pin Lemo connector size 1.
Product information
SAM-Module slots: |
5 |
Auxiliary energy: |
9 ... 18V DC |
Power consumption: |
< 8W |
AC / DC Adapter: |
100-240VAC |
Dimension: |
ca.165x160x45mm |
Connectors: |
BNC or Lemo 4p Gr.1 |
Adapters for measurement boards: |
Data Translation DT300, Goldammer MultiChoice, National Instruments 68p |
Technical Data: |
|
|
SAM System case S2 - case for 7 SAM Module carriers |
 |
The SAM system case S2 has a rugged aluminium case and 7 slots for SAM-MC module carriers, each for two
SAM modules (Miniaturized Signal Conditioning Modules). It also contains a wide range power supply unit
and an universal 25-pin D-SUB adapter to connect the output signals of the SAM amplifiers to a data acquisition
board. With a S2 system case it is possible to build up signal conditioning systems with max. 14 analog input channels.
Product information
SAM-Module carriers: |
7 slots for 2 channel module carriers SAM-MC |
Auxiliary energy: |
100 .. 230V AC |
Power consumption: |
<30W |
Dimension: |
ca.257x111x256mm (WxHxT) |
Adapter to measurement boards: |
Universal 25-pin D-Sub connector |
Technical Data (German only): |
User manual for S2 and S3 (German only): |
|
|
SAM System case S3 - case for 7 SAM-MC with integrated USB module |
|
|
The SAM system case S3 has a rugged aluminium case with an integrated data acquisition module and 7 slots for SAM-MC module carriers, each for two
SAM modules (Miniaturized Signal Conditioning Modules). It also contains a wide range power supply unit.
With a S3 system case it is possible to build up signal conditioning systems with max. 14 analog input channels.
Product information
SAM-Module carriers: |
7 slots for 2 channel module carriers SAM-MC |
Auxiliary energy: |
100 .. 230V AC |
Power consumption: |
<30W |
Dimension: |
ca.257x111x256mm (WxHxT) |
Data Acquisition: |
USB-Basic, ECON or DT980x also available with Ethernet-, Bluetooth- or Com-Modules |
Technical Data (German only): |
User manual for S2 and S3 (German only): |
|
|
SAM-MC - Module carrier for system cases S2 and S3 |
 |
The SAM-MC module carrier has two free slots for SAM modules. The input signal of each SAM module
is wired to a connector placed in the front plate of the module carrier. Available are front plates
with isolated BNC connectors, Lemo connectors size 1 or mini thermo connectors. The internal system
connector supplies the SAM modules and transfers the output signals of the SAM amplifiers to the
data acquisition modules (S3) or to the connector in the rear panel of the system case (S2).
SAM-MC-BNC |
Connect signals via 2 isolated BNC connectors |
SAM-MC-L12 |
Connect signals via 2 Lemo size 1, 2-pins |
SAM-MC-L14 |
Connect signals via 2 Lemo size 1, 4-pins |
SAM-MC-MTJ |
Connect signals via 2 mini thermo con. Type J |
SAM-MC-MTK |
Connect signals via 2 mini thermo con. Type K |
SAM-MC-D01 |
Module carrier for digital I/O 4 dig. inputs 12-24VDC
2 dig. outputs 12-24VDC, 0,5A Signal connector 9-pin D-Sub connector |
Technical Data :
 |
|
|
SAM101 - Voltage input with galvanic isolation |
 |
Signal module with active signal processing and galvanic isolation, capacitive signal transmission, isolation barrier voltage 1000V DC, bandwidth max. 10KHz,
lowpass filter 2. order
Input Ranges: |
±500mV, ±1V, ±5V, ±10V, ±20V, ±30V, ±50V |
Output Range: |
±10V |
Signal bandwidth: |
100Hz, 1000Hz, 5000Hz, 10000Hz |
Technical data:
 |
|
|
SAM102 - Voltage input with galvanic isolation |
 |
Signal module with active signal processing and galvanic isolation, inductive signal transmission, isolation barrier voltage 1000V DC, bandwidth max. 1KHz,
lowpass filter 2. order
Input Ranges: |
±500mV, ±1V, ±5V, ±10V, ±20V, ±30V, ±50V |
Output Range: |
±10V |
Signal bandwidth: |
100Hz, 1000Hz |
Technical data:
 |
|
|
SAM131 - Voltage input without galvanic isolation |
 |
Signal module with active signal processing without galvanic isolation, differentiell input amplifier, bandwidth max. 10KHz,
lowpass filter 2. order
Input Ranges: |
±500mV, ±1V, ±5V, ±10V, ±20V |
Output Range: |
±10V |
Signal bandwidth: |
100Hz, 1000Hz, 5000Hz, 10000Hz |
Technical data:
 |
|
|
SAM401 - Voltage input without active signal conditioning |
 |
Signal module without active signal processing, input overvoltage protection
Input Ranges: |
±10V |
Output Range: |
±10V |
Signal bandwidth: |
not defined |
Technical data:
 |
|
|
SAM111 - Current input with galvanic isolation |
 |
Signal module with active signal processing and galvanic isolation, capacitive signal transmission, isolation barrier voltage 1000V DC, bandwidth max. 1KHz,
lowpass filter 2. order
Input Ranges: |
±20mA |
Output Range: |
±10V |
Signal bandwidth: |
100Hz, 1000Hz |
Technical data:
 |
|
|
SAM112 - Current input with galvanic isolation |
 |
Signal module with active signal processing and galvanic isolation, inductive signal transmission, isolation barrier voltage 1000V DC, bandwidth max. 1KHz,
lowpass filter 2. order
Input Ranges: |
±20mA |
Output Range: |
±10V |
Signal bandwidth: |
100Hz, 1000Hz |
Technical data:
 |
|
|
SAM132 - Current input without galvanic isolation |
 |
Signal module with active signal processing without galvanic isolation, differentiell input amplifier, bandwidth max. 1KHz,
lowpass filter 2. order
Input Ranges: |
±20mA |
Output Range: |
±10V |
Signal bandwidth: |
100Hz, 1000Hz |
Technical data:
 |
|
|
SAM402 - Current input without active signal conditioning |
 |
Signal module without active signal processing, input overvoltage protection
Input Ranges: |
±20mA |
Output Range: |
±10V |
Signal bandwidth: |
not defined |
Technical data:
 |
|
|
SAM190 - RTD100 without galvanic isolation |
 |
Signal module with active signal processing without galvanic isolation for RTD100 transmitter, differentiell input amplifier,
impressed current of 0.5mA for sensor supply, bandwidth max. 10Hz, lowpass filter 2. order
Input Ranges: |
RTD100 ±150°C, ±400°C |
Output Range: |
±10V |
Signal bandwidth: |
10Hz |
Technical data:
 |
|
|
SAM141 - Thermocouple Type J with galvanic isolation |
 |
Signal module with active signal processing with galvanic isolation for Thermocouple Type J, switchable cold
junction, isolation barrier voltage 1000V DC, bandwidth max. 10Hz, lowpass filter 2. order
Input Ranges: |
Typ J 0-750°C |
Output Range: |
0-10V |
Signal bandwidth: |
10Hz |
Technical data:
 |
|
|
SAM146 - Thermocouple Type K with galvanic isolation |
 |
Signal module with active signal processing with galvanic isolation for Thermocouple Type K, switchable cold
junction, isolation barrier voltage 1000V DC, bandwidth max. 10Hz, lowpass filter 2. order
Input Ranges: |
Typ K 0-500°C, 0-1000°C |
Output Range: |
0-10V |
Signal bandwidth: |
10Hz |
Technical data:
 |
|
|
SAM158 - ICP without galvanic isolationg |
 |
Signal module with active signal processing without galvanic isolation for ICP accelerometers,
impressed current of 4mA for sensor supply, max. suplly voltage 30V, bandwidth max. 20KHz, lowpass filter 1. order
|
Input Ranges: |
ICP-Signal ±10V |
Output Range: |
±10V |
Signal bandwidth: |
20KHz |
Technical data:
 |
|
|
SAM151 - Strain gages with instrumentation amplifier |
 |
Signal module with active signal processing without galvanic isolation for strain gages (full bridge), reference voltage
10V, differentiell input amplifier, zero and full scale calibration with potentiometers, jumper selectable
gain values, lowpass filter 2. order
Input Ranges: |
±20mV and ±50mV (2mV/V order 5mV/V) |
Output Range: |
±10V |
Signal bandwidth: |
100Hz, 1000Hz, 5000Hz |
Technical data:
 |
|
|
SAM501 - Butterworth low pass filter fourth order |
 |
Signal module with active signal processing without galvanic isolation, lowpass filter fourth order
differentiell input amplifier, fixed cut off frequence
Input Ranges: |
±5V, ±10V |
Output Range: |
±10V |
Signal bandwidth: |
1100Hz, 500Hz, 1000Hz, 5000Hz, 10KHz |
Technical data:
 |
|
|
Drawing
 |
Bedo Elektronik GmbH |
Ennsstrasse 19 |
D-47809 Krefeld |
Tel: 0049-(0)2151-548183 / Fax: 0049-(0)2151-541978 / Email: info@bedogmbh.de |
© 2008 Bedo Elektronik GmbH |
Specifications subject to change without notice.
| E-Mail: info@bedogmbh.de
|
|